Request a Quote

Bipolar Ionization for Commercial HVAC

Cleaner air inside the HVAC system — no filters to replace, no ozone to worry about.

Carevient duct-mounted bipolar ionizers treat air as it moves through the system — for offices, schools, healthcare and commercial buildings across Europe and North America. One compact module per air stream, 1–5 W of power, and nothing to change or wash.

Ozone < 0.005 ppm — laboratory tested No replacement parts 110–240 V for EU & US projects 15,000-hour module life
>94%bacterial killing*
>90%odour removal*
>90%formaldehyde removal*
<0.005 ppmozone — laboratory tested

* Manufacturer-published third-party laboratory results for the KYOG220V01GP module under controlled laboratory conditions. Actual performance varies with airflow, pollutant load and installation. Test reports are available on request for the selected model.

Featured Products

Three modules for every HVAC application

Pick by airflow and voltage — one module treats up to 1,000 m³/h. For larger air handlers, we size the number and placement of modules for you.

KYOG220V01GP duct and AHU bipolar ionizer — 24-pin needlepoint module

KYOG220V01GP — Duct & AHU Ionizer

AC 220 V · 24-pin needlepoint · <1,000 m³/h · 3–5 W

The standard duct and air-handler module. 24 needlepoint emitters, third-party laboratory tested performance, and a 15,000-hour life. The workhorse for EU commercial projects on 220 V mains.

KYOG220V02GP high-density duct ionizer — 37-pin needlepoint module

KYOG220V02GP — High-Density Duct Ionizer

220 V AC / 12 V DC · 37-pin needlepoint · >200M ions/cm³ · <3 W

Our highest ion output in the smallest package. 37 pins delivering over 200 million ions/cm³ for central AC ducts, fan coil units and air handlers — with dual-voltage input for 220 V AC or 12 V DC systems.

KYOG110V04GP brush bipolar ionizer for North America — carbon-fibre brush module

KYOG110V04GP — Brush Ionizer for North America

110 V AC · carbon-fibre brush · <1 W · zero-ozone design

Built for the US market: 110 V / 60 Hz, under 1 W, and a carbon-fibre brush emitter designed to meet the UL 2998 zero-ozone standard. The compact choice for VRF, PTAC and ductless systems — 220 V versions available on request.

Compare all three →

Applications

Where it works

Duct-mounted or air-handler-mounted — the modules go where the air already moves.

Rooftop air handling units on a commercial building

Commercial Buildings

Offices, malls and mixed-use towers: treat supply air at the AHU and improve the air every tenant breathes, without adding filter changes to the maintenance schedule.

Duct / AHU
Empty classroom with rows of desks

Schools & Education

Classrooms and lecture halls with high occupancy and limited ventilation: continuous ion treatment in the supply air, with no consumables for facility teams to manage.

Duct / AHU / FCU
Hospital corridor

Healthcare

Clinics, waiting rooms and care facilities: bipolar ionization as part of the air-quality strategy, with ozone below 0.005 ppm in laboratory testing.

Duct / AHU
Modern open-plan office interior

Offices & Workspaces

Open-plan offices and meeting rooms: reduce odours and airborne particles in the recirculated air, and support the building's indoor air quality goals.

Duct / FCU / VRF
Hotel lobby

Hospitality & Retail

Hotels, restaurants and shops: fresher air for guests and customers, and odour control in kitchens, lobbies and high-traffic areas.

Duct / FCU
Air handling unit in a plant room

FCU, VRF & PTAC

Fan coils, variable-refrigerant systems and packaged terminal units: the compact brush module fits where a duct module cannot.

KYOG110V04GP

How It Works

Bipolar ionization in three steps

  1. Ions are created. As dirty air is drawn through the plasma region, needlepoint or brush emitters release balanced positive and negative ions into it.
  2. Contaminants are broken down. Ions attach to airborne particles, VOCs and odour molecules. Particles cluster together, making them easier for the existing filter to catch.
  3. Cleaner air, continuously. Clean air flows on into the occupied space, so treatment continues around the clock — with no filter to replace and no consumables.
Schematic animation: the fan draws dirty air through the plasma region — ions are created, attach to particles, and clean air flows into the room.

How bipolar ionization works →

Why Engineers Specify Carevient

Built for the project, not the shelf

Compliance & Trust

What we can stand behind

Ozone: laboratory-tested ozone output below 0.005 ppm for the KYOG220V01GP and KYOG110V04GP modules. The KYOG110V04GP brush module is designed to meet the UL 2998 zero-ozone standard. The U.S. EPA recommends choosing air-cleaning devices that meet the UL 2998 standard for zero ozone emissions.

Certifications: CE, EMC and RoHS as listed by the manufacturer for the applicable modules. Test reports are available on request for the selected model — ask us and we will provide the matching report for your project.

Honest note: performance figures on this site are the manufacturer's published laboratory data, shown as manufacturer data. We do not present third-party test reports as our own, and we do not promise results for conditions that have not been tested.

Distributors & OEM / ODM

For distributors, contractors and equipment makers

We supply the modules — you supply the market. Samples, datasheets and project pricing are available before you commit to volume.

  1. Send an inquiry. Tell us the application, airflow and voltage. We recommend the module and quote the project.
  2. Test a sample. Order a sample module and datasheet pack. Test it in your own duct or air handler.
  3. Customise. Private label, custom voltage, packaging and documentation for your market.
  4. Scale up. Mass production with consistent quality and ongoing supply for your projects.

Become a distributor →

Have a project in mind?

Tell us the building, the airflow and the voltage — we will recommend the module and quote it.

Request a Quote Download Datasheets