Airborne particles
Ions charge fine particles so they cluster and are captured more easily by the system's existing filter — without adding pressure drop to the duct.
Technology
Instead of adding another filter to change, bipolar ionization treats the air as it passes through the module. The fan downstream draws air through the module, keeping it under negative pressure, so dirty air is pulled through the plasma region around the emitters.
What It Addresses
Ions charge fine particles so they cluster and are captured more easily by the system's existing filter — without adding pressure drop to the duct.
Ions help break down odour molecules and volatile organic compounds in the airstream, for fresher air in offices, schools, hotels and restaurants.
Manufacturer-published third-party laboratory results for the KYOG220V01GP module report bacterial killing above 94% under controlled laboratory conditions. Test reports are available on request for the selected model.
Laboratory figures are manufacturer-published data under controlled conditions. Actual performance varies with airflow, pollutant load and installation — we do not promise a single percentage for every building.
Ozone & Safety
Not every ionizer is safe to run in an occupied building — some generate ozone, a lung irritant. Carevient modules are designed to keep ozone far below the levels that matter:
Installation
KYOG220V01GP and KYOG220V02GP mount in the supply duct or inside the air handler, upstream of the fan, so the fan draws air through the module and the treated air is distributed with the supply air. One module treats up to 1,000 m³/h; larger handlers take more than one module across the airstream.
KYOG110V04GP's 80 mm brush module fits fan coil units, VRF indoor units and PTAC units — the systems where a duct module cannot go. It runs on 110 V AC for North America, with 220 V versions on request.
Modules are installed by a qualified HVAC technician as part of the system's electrical work. Tell us the duct size, airflow and system type in your inquiry and we will recommend the module, the quantity and the placement.
Indoor Air Quality Strategy
Engineers use air cleaning as one part of an indoor air quality strategy, alongside ventilation and filtration — for example under the Indoor Air Quality Procedure of ASHRAE Standard 62.1, which allows air cleaning to be considered when designing ventilation for a building. Bipolar ionization fits that approach: it treats the air in the system that is already there, without adding filter pressure drop or a new maintenance routine.
Ask our engineers for application guidance for your building type — commercial, school, healthcare, office or hospitality — and we will recommend the module and the layout.
From Sample to Mass Production
Ionizer modules are available as components for your own purifier or HVAC line — with your brand, your voltage and your documentation.
See the Modules