Three bipolar ionizers, sized by airflow and voltage

One module treats up to 1,000 m³/h. For larger air handlers, we size the number and placement of modules for your project — tell us the airflow and we will recommend the layout. Prices are quoted per project; send an inquiry and we will reply with a model recommendation and a quotation.

ModelBest forInput voltageIon outputAirflowPowerSize
KYOG220V01GPDuct & AHU, EU commercialAC 220 V / 50 Hz>15M ions/cm³<1,000 m³/h3–5 W150 × 90 × 60 mm
KYOG220V02GPCentral AC ducts, FCU, AHU220 V AC / 12 V DC>200M ions/cm³≤1,000 m³/h<3 W95 × 75 × 60 mm
KYOG110V04GPVRF, PTAC & ductless, US110 V AC (220 V on request)>15M ions/cm³<1,000 m³/h<1 W80 × 25 × 32 mm
KYOG220V01GP duct and AHU bipolar ionizer — 24-pin needlepoint module

KYOG220V01GP — Duct & AHU Ionizer

24-pin needlepoint bipolar ionizer · AC 220 V / 50 Hz · <1,000 m³/h

The standard duct and air-handler module for EU commercial projects. 24 needlepoint emitters generate positive and negative ions that break down odours and VOCs and reduce airborne bacteria and particles. Third-party laboratory tested, with a 15,000-hour service life and no replacement parts.

Input voltageAC 220 V / 50 Hz
Output voltage−10 kV (maximum)
Ion concentration>15 × 10⁶ ions/cm³
Power consumption3–5 W
Input current150–200 mA
Applicable airflow<1,000 m³/h
Ozone output<0.005 ppm (laboratory tested)
Laboratory results*Bacterial killing >94% · Odour removal >90% · Formaldehyde removal >90%
Service life15,000 hours
Dimensions / weight150 × 90 × 60 mm · 0.5 kg
Compliance (manufacturer)UL, CUL, ETL, CE, CB, EMC, RoHS, REACH as listed by the manufacturer
Best forCommercial buildings, schools, healthcare, offices — duct and AHU mounting
EU · 220 V / 50 HzNeedlepoint · 24-pinNo consumables
KYOG220V02GP high-density duct ionizer — 37-pin needlepoint module

KYOG220V02GP — High-Density Duct Ionizer

37-pin needlepoint bipolar ionizer · 220 V AC / 12 V DC · >200M ions/cm³ · <3 W

Our highest ion output in the smallest package. 37 needlepoint emitters deliver over 200 million ions/cm³ for central air-conditioning ducts, fan coil units and air handlers. Dual-voltage input covers 220 V AC mains and 12 V DC systems, and the 95 mm body fits tight duct spaces.

Input voltage220 V AC / 12 V DC, 50/60 Hz
Output voltage−6.5 kV
Ion concentration>200 × 10⁶ ions/cm³
Power consumption<3 W
Input current110 V: 0.05–0.1 A · 12 V: 0.2–0.3 A
Applicable airflow≤1,000 m³/h
Ozone output<0.005 ppm
Service life15,000 hours
Dimensions / weight95 × 75 × 60 mm · 0.3 kg
Compliance (manufacturer)UL, CUL, ETL, CE, CB, EMC, RoHS, REACH as listed by the manufacturer
Best forCentral AC ducts, fan coil units, air handlers — where the highest ion density is needed
Dual voltageNeedlepoint · 37-pinCompact · 95 mm
KYOG110V04GP brush bipolar ionizer for North America — carbon-fibre brush module

KYOG110V04GP — Brush Ionizer for North America

Carbon-fibre brush bipolar ionizer · 110 V AC / 60 Hz · <1 W · zero-ozone design

Built for the US market and for ductless systems. A carbon-fibre brush emitter — the same approach used by leading North American HVAC ionizer brands — designed to meet the UL 2998 zero-ozone standard, drawing under 1 W. At 80 mm long it fits fan coils, VRF indoor units and PTAC units where a duct module cannot go. 220 V versions are available on request.

Input voltage110 V AC (220 V AC / custom on request)
Output voltage−7.5 kV
Ion concentration>15 × 10⁶ ions/cm³
Power consumption<1 W
Input current≤0.01 A
Applicable airflow<1,000 m³/h
Ozone output<0.005 ppm — designed to meet UL 2998 zero-ozone requirements
Service life15,000 hours
Dimensions / weight80 × 25 × 32 mm · 0.1 kg
Compliance (manufacturer)UL, CUL, ETL, CE, CB, EMC, RoHS, REACH as listed by the manufacturer
Best forVRF, PTAC, ductless and mini-split systems; fan coils; US 110 V / 60 Hz projects
US · 110 V / 60 HzBrush emitter<1 W

* Laboratory results for the KYOG220V01GP are manufacturer-published third-party laboratory results under controlled laboratory conditions. Actual performance varies with airflow, pollutant load and installation. Test reports are available on request for the selected model.

How to size it

Each module treats up to 1,000 m³/h of airflow. For a larger air handler, use more than one module and place them across the airstream — tell us the airflow, duct size and system type in your inquiry and we will recommend the number and placement. All three modules are also available for OEM/ODM private-label projects with custom voltage and branding.

Datasheets

KYOG220V01GP

Duct & AHU ionizer — full specifications, dimensions, applications and compliance notes.

Download PDF

KYOG220V02GP

High-density duct ionizer — full specifications, dimensions, applications and compliance notes.

Download PDF

KYOG110V04GP

Brush ionizer for North America — full specifications, dimensions, applications and compliance notes.

Download PDF
About the figures on this page: airflows, ion concentrations, power and dimensions are the rated specifications published by the manufacturer for each model. Performance in a real building depends on airflow, ventilation and pollutant load. Test reports and certificates for a specific model are available on request — please mention the model in your inquiry.

Don't see your size or voltage?

Most modules can be customised — voltage, airflow, size, logo and packaging. Tell us what you need.

Contact Us